ACETONE, QUANTITATIVE Mnemonic MISC Guidelines For Urine Alcohols, please see ALCOHOL(S). Specimen Collection Requirements Patient Preparation Use iodine swab to clean draw site. DO NOT use isopropyl alcohol wipe. Collect Preferred: Whole Blood, one 4.0 mL gray top tube (sodium fluoride/potassium oxalate). Also acceptable: Serum or Plasma, one 7.0 mL red, one 4.0 mL dark green (sodium heparin) or one 4.0 mL lavender (EDTA) top tube. Handling Preferred: Submit entire unopened specimen. Refrigerate 2-8°C. If processed, make sure specimen has not been uncapped except to transfer to a clean tightly capped test tube. Preferred Volume 4 mL whole blood, 2 mL serum or plasma Minimum Volume 2 mL whole blood, 1 mL serum or plasma Transport Refrigerated (2-8 °C) Rejection Criteria Specimens below the minimum volume. Stability Ambient (20-25ºC): 24 hours; Refrigerated (2-8ºC): 72 hours; Frozen (at or below -20º): 2 weeks Testing Information Performed 7 days/week Reported 24 hours Method Headspace Gas Chromatography-Flame Ionization Detector Reference Values Reference Values Not Detected (<10 mg/dL) Toxic Levels >40 mg/dL (plasma/serum) CPT Codes 80320; G0480 Last Updated: Thursday, January 5, 2017 03:41:54 AM