Culture, Lines/Hardware

Mnemonic

C LINES

Includes

Colony count on line cultures only.

Guidelines

Use this order for line tip cultures, or small implanted hardware items. When ordering catheter tip cultures, submit concurrent Blood Cultures. Foley catheter tips are unacceptable.

Specimen Collection Requirements

Patient Preparation

Prep skin before catheter removal.

Collect

Using aseptic technique, cut the distal 5 cm (2 inches) of line into a sterile screw-cap container. Aseptically place small hardward piece into sterile screw-cap container.

Handling

Deliver immediately to the lab.

Preferred Volume

5 cm (2 inch) distal cath tip

Minimum Volume

1 cm distal cath tip

Transport

Ambient

Rejection Criteria

Leaking or nonsterile container, Foley catheter

Stability

Ambient: 2 hours; Refrigerated: 24 hours

Testing Information

Performed

7 days/week

Reported

Final: 2-3 days

Method

Standard Aerobic Bacterial Culture

Reference Values

Reference Values

Less than 15 colonies

Comments

Results indicate colony count and identification of significant isolates.  Since treatment of catheter infection is removal of device, susceptibilities are NOT done on tips, refer to susceptibilities on concurrent blood cultures.  Additional charges for identification of organisms (CPT 87077).  Susceptibility tests are performed by request only (CPT 87186, 87184, 87181, 87147).

CPT Codes

87070, (87077, 87186, 87184, 87181, 87147 as needed)